Senseca ECO 230 handleiding

20 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 9 van 20
ECO 230 barometer | altimeter
Operation
B-H88.0.01.DK2-2.1 Page 9 of 20
4 Operation
4.1 Opening the configuration menu
1 Press the Function key for 2 seconds to open the Configuration menu.
2 (ONF appears in the display. Release the Function key.
Parameter
Values
Meaning
UN,T
Display unit
HPa
Barometer in [hPa]
mBaR
Barometer in [mbar]
PSI
Barometer in [psi]
mmKG
Barometer in [mmHg]
m
Altimeter/Elevation display in [m]
FT
Altimeter/Elevation display in [feet]
RATE
Measuring rate
SLO
Slow measurement speed
FAST
Fast measurement speed
(not recommended for altimeter display)
SEA.L
SeaLevel-correction (not available at altimeter/elevation display)
NO
Inactive, display measured air pressure directly
YES
Active, display air pressure compensated to sea level
ALT,
High above sea level
-500 .. 9000
Height above sea level in m for correction
At altimeter: default value for altitude input
TEND
Trend display
OFF
Bar display and tendency value display deactivated