ECO 230 barometer | altimeter
Technical data
B-H88.0.01.DK2-2.1 Page 18 of 20
9 Technical data
Measuring
range
Barometer
300.0 .. 1100.0 hPa (mbar) abs.
4.350 .. 15.950 PSI abs.
225.0 .. 825.0 mmHg (Torr) abs.
Altimeter
-500.0 .. 9000.0 m
-1640 .. 19999 ft.
Temperature
-20.0 .. 50.0 °C
-4.0 .. 122.0 °F
Accuracy
Barometer
± 1 hPa typical (at T: 0 .. 30 °C)
± 0.25 % FSS max. corresponds ± 2 hPa
Altimeter
typ. ± 1 m relative (over a short period at constant
ambient pressure @ 25°C)
Temperature
typ. ± 0.5 °C @ 25°C
Overload
4000 hPa abs.
Measuring medium
Air
Pressure connection
No connection, integrated sensor
Pressure equalization via diaphragm-protected opening
Measuring cycle
FAST: approx. 2.5 measurements per second
SLO: approx. 4 seconds
Display
3-line segment LCD, additional symbols, illuminated
(adjustable white, permanent illumination)
Standard function
Min/Max/Hold
Trend display, time base selectable (1s, 60s, 1h, 3h)
corresponds to Altimeter Variometer display with units
m/s, ft/min, m/h, ft/h
Only with altimeter function:
The altitude meters covered are calculated (ascent AS(,
descent DES(, resolution 1m)
Additional functions
NVLL: Tare function
Adjustment
Zero point and gradient adjustment