ECO 123 - Ambient thermometer
Technical data
B-H86.0.09.DK2-1.1 Page 15 of 18
8 Technical data
Measuring range
-25.0 .. +70.0 °C (-13.0 .. +158.0 °F).
Accuracy
± 0.5 % of measured value ± 0.5 °C
Response time t
90
approx. 15 sec. (at air 2 m/s)
Measuring cycle
approx. 2 measurements per second
Display
3-line segment LCD, additional symbols, illuminated (white,
luminous duration adjustable)
Standard functions
Min/max/hold,
alarm (optical and acoustic)
Adjustment
Offset and gradient correction
Housing
Break-proof ABS housing
Protection rating
IP20
Dimensions L*W*H
108 (141) * 54 * 28 mm, without (with) sensor head
Weight
~ 126 g incl. batteries
Nominal temperature
25 °C
Operating conditions
-20 to 50 °C; 0 to 95 %RH (temporarily condensing)
Storage temperature
-20 bis 70 °C
Current supply
2 * AA batteries (mignon)
Current requirement
approx. 0.4 mA, approx. 2 mA with backlight
Battery life
Service life > 5000 hours with alkaline batteries
(without backlighting)
Battery indicator
4-stage battery status indicator,
Replacement indicator for depleted batteries: "BAT"
Auto-power-OFF
function
The device switches off automatically if this is activated