Maintenance
The following maintenance procedures should be followed to ensure the longevity of your FKR-A Series
double impulse portable sealer.
Inspection and Cleaning
1. Inspect your machine daily.
2. Use a clean cloth to remove any plastic residue remaining on the PTFE cloth.
3. When replacing the elements, always check the condition of the bottom PTFE tape.
4. Check the condition of the silicone rubber for wear and burns. A damaged silicone rubber will
affect the quality of the seal.
Replacement Kit Instructions
Our FKR-A Series double impulse sealers will require new heating elements and PTFE from time to time.
Heating elements will break through wear and tear. A good rule of thumb is to replace the PTFE adhesive
every time you change your heating element. The PTFE cover prevents the plastic or other thermoplastic
material you are sealing from sticking to the heating element.
Replacement kits are available from your distributor. Kits include (2) heating elements, (2) PTFE Covers,
and (2) PTFE adhesives. For replacement kit part #s, refer to your model #.
FKR-200A
FKR-300A
FKR-400A
Replacement Kit
RK-8H5-FKR-200A
RK-12H5-FKR-300A
RK-12H5-FKR-400A
Heating Element
HE-8-5-FKR-200A
HE-12-5-FKR-300A
HE-16-5-FKR-400A
PTFE Adhesive
TA-8
TA-12
TA-16
PTFE Cover (1" wide)
TC-8-1
TC-12-1
TC-16-1