Chapter 2 User commands 17
setcanisterstr
Command
setcanisterstr
[
state
]
Command synopsis Changes the local I/O module safe-to-remove status.
Command description Changes an application/RAID I/O module's safe-to-remove indication status. This state is usually managed
by GEM's processor service.
The method for displaying this status may vary on a per product basis. See the product’s installation
procedures for specific details.
Command parameters
state
l
1 sets the safe-to-remove indicator state to ON.
l
0 sets the safe-to-remove indicator state to OFF.
l
If no parameters are specified: the current state of the local I/O module’s safe-to-remove indicator
state is returned.
Command type Control
Access level General
Applicable products Exos AP, Nytro AP
Supported in versions 2.0 or later
Current status Active
settime
Command
settime [format <parameters>]
Command synopsis Sets current time on the enclosure.
Command description Sets or reports the current time of the enclosure. Two time-stamp formats are supported:
l
Relative time: This is a timestamp expressed as the number of days, hours, minutes, seconds and
milliseconds since a given epoch.
l
Calendar time: This is a timestamp expressed as the full Gregorian calendar year, month, day, hour,
minute and second, with the earliest representable date being 1970-01-01 00:00:00.
I/O modules not fitted with a real-time clock default to reporting relative time, where the epoch is the point