Scotsman UC0918GA-1AX handleiding

29 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 21 van 29
UC GOURMET UNDERCOUNTER
pg. 22
180 seconds Up to 6 min
30 sec
*** Up to 9 min
30 sec
***
165 seconds 6 min 30 sec
7 min
Up to 3 min 9 min 30
sec – 10 min
***
150 seconds 7-8 min 3 min 3
min 15 sec
10-11 min ***
135 seconds 8-9 min 3 min 15
sec – 3 min
30 sec
11-12 min ***
120 seconds 9 min - 10 min
30 sec
3 min 30
sec – 4 min
30 sec
12 min 13
min 30 sec
˂3 min
105 seconds 10 min 30 sec
12 min
4 min 30
sec – 6 min
13 min 30
sec – 15 min
3-4 min
90 seconds ˃12 min ˃6 min ˃15 min ˃4 min
The DIP SWITCH keys 7 & 8 setting allow the extension of the length of the harvest/defrost
cycle according
to their combination as per the following chart:
DIP SWITCH ADDITIONAL DEFROST TIME
7 8
ON ON 0
OFF ON 30 seconds
ON OFF 60 seconds
With both the DIP SWITCH 7 & 8 in OFF position, the water pump is OFF during the harvest cycle with no
additional time.
The 9
th
key is used to supply power to the water pump for the first 15 seconds of the defrost cycle
position OFF or for the first 30 seconds position ON.
The 10
th
key is used to modify the CUT-OUT condensing temperature from 160˚F (70˚C) – ON position.
HARVEST
CYCLE LENGTH
PROGRAMS
A B C D
LENGTH OF THE HARVEST CYCLE ACCORDING TO THE TIME TO DROP THE EVAP TEMP FROM 32˚F (0˚C) TO
5˚F (-15˚C)