Scotsman UC0918GA-1AX handleiding
Handleiding
Je bekijkt pagina 19 van 29

UC GOURMET UNDERCOUNTER
pg. 20
f. LED Meaning
• GREEN LED ON – unit powered ON
• YELLOW BIN FULL LED ON – unit shut OFF with full bin
• RED ALARM LED ON – high condensing temperature
• RED ALARM LED BLINKING – high evaporating temperature
• YELLOW FREEEZE CYCLE ON – unit in freeze cycle mode
• YELLOW FREEZE LED AND RED ALARM LED ON – condenser sensor
malfunction
• YELLOW FREEZE LED AND RED ALARM LED BLINKING – evaporator sensor
malfunction
LED
STATUS REASON WHY
ON STEADY UNIT UNDER POWER
ON STEADY FREEZE CYCLE
BLINKING 60 MINUTES DELAY AT START UP
JUMPER J3 OUT
ON STEADY HIGH DISCHARGE PRESSURE/TEMP
BLINKING HIGH EVAP TEMP (>32˚F/0˚C) AFTER
15 MINUTES FROM START UP
ON STEADY UNIT OFF AT BIN FULL
BLINKING UNIT IN CLEANING MODE OR
TRIPPING OFF AFTER TEST – JUMPER
TEST IN
Bekijk gratis de handleiding van Scotsman UC0918GA-1AX, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Scotsman |
Model | UC0918GA-1AX |
Categorie | Niet gecategoriseerd |
Taal | Nederlands |
Grootte | 5812 MB |