Scotsman Prodigy Plus N0922 handleiding

37 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 23 van 37
Status List
Press and release the down arrow to underline the S in Status.
Press and release the Enter button to see:
Warranty Start
: The display will show the warranty start date after 24 hours of
run time. Press and release the Down arrow to see:
Relay Voltage
: Voltage supplied to the relays. Press and release the Down
arrow key to see:
Board Voltage
: Voltage supplied to operate the controller. Press and release
the Down arrow key to see:
Auger Motor Current
: Current draw of the auger drive motor. Press and
release the Down arrow key to see:
Auger Motor Trip Current
: Maximum allowed amp draw. Press and release
the Down arrow key to see:
Auger Motor Strikes
: Number of times auger motor has currently exceeded
the amp draw setpoint. Press and release the Down arrow key to see:
Ice Making Sensed
: Has the controller sensed ice making? Press and release
the Down arrow key to see:
Ice Making Strikes
: Number of times the controller has not sensed ice falling
in the chute. Press and release the Down arrow key to see:
Freeze Timer
: Current compressor on time in minutes. Press and release the
Down arrow key to see:
KVS Level
: Distance in inches the ice level control system has measured from
the sensor to the top of the ice. Press and release the Down arrow key to see:
KVS Level Setpoint
: Distance in inches the ice level system will maintain as a
maximum ice level. Press and release the Down arrow key to see:
Power Interrupt Counter
: Number of times power has been interrupted to the
machine. Press and release the Down arrow key to see:
Bin Stat Input
: Shows Closed if no bin thermostat is attached or if one is
attached and is Closed. Shows open only if there is a bin thermostat attached
and it is open, which stops ice making. When done with Status, press and
release the ESC button.
August 2011
Page 7
NB0622, NB0922, FB1222, NB1322
Information Display
Relay Voltage:
240 VAC
Board Voltage:
14 VAC
Auger Mot Current
1.8 Amps AC
Aug Mot Trip Curr
3.0 Amps AC
Ice Making Sensed
Yes
Ice Making Strikes
0
Freeze Timer:
00:00
KVS Level
00:00
KVS Level Setpoint
0
Pwr Interrupts
0
Bin Stat
Opem
Adv Faults
S
tatus
Auger Mot Strikes
0
Warranty Start:
Starts at 24HRS

Bekijk gratis de handleiding van Scotsman Prodigy Plus N0922, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkScotsman
ModelProdigy Plus N0922
CategorieNiet gecategoriseerd
TaalNederlands
Grootte5062 MB