MC0322 through MC1030
Air and Water Cooled User Manual
June 2022
Page 2
Installation: Product Specications
Location Limitations:
The product is designed to be installed indoors, in a
controlled environment. Air cooled models discharge
very warm air into the room out the back. Space must
be allowed at the sides and back for air discharge.
Water cooled models discharge warm water into the
building’s drain.
Space needs to be provided on both sides and above
for service access.
Space Limitations
Note: Although the machine will function, ice capacity
of air cooled machines will be signicantly reduced
with minimal clearance at the sides, back and top.
Some space is recommended for service and
maintenance purposes on all models. 6" of space
at the sides and back are required for adequate
operation. To get the most capacity, locate the
machine away from heat producing appliances and
heating ducts, and allow 12-18 inches of space at
the sides and top for good air ow.
Airow is in the front, out the back. Attach a ba󰀪e kit
to the back when an air cooled unit is installed with
minimal side and top clearance. See the next page for
kit numbers.
Environmental Limitations
Minimum Maximum
Air temperature 50
o
F. 100
o
F.
Water temperature 40
o
F. 100
o
F.
Water pressure 20 psi 80 psi
Power supply – acceptable voltage ranges
Minimum Maximum
115 volt model 104 volts 126 volts
208-230 volt model 198 volts 253 volts
Warranty Information
The warranty statement for this product is provided
separately from this manual. Refer to it for applicable
coverage. In general warranty covers defects
in material or workmanship. It does not cover
maintenance, corrections to installations, or situations
when the machine is operated in circumstances that
exceed the limitations printed above.
Product Information
This product is a modular cuber. This type of machine
is designed to be placed on an ice storage bin or
an ice dispenser. Many installations only require the
matching bin, but some also require an adapter to
be placed between the bin and the cuber or between
the dispenser and the cuber. This product cannot
be stacked. See the chart on the next page for
application information.