Installation: Product Specifications
Location Limitations:
The product is designed to be installed indoors, in
a controlled environment. Air cooled models
discharge very warm air into the room. Water
cooled models discharge warm water into the
building’s drain. Space needs to be provided for
service access.
Space Limitations
Do not block air flow at the front.
Airflow is in the front left and out the front right.
Environmental Limitations
Minimum Maximum
Air
temperature
10
o
C. 38
o
C.
Water
temperature
4
o
C. 38
o
C.
Water
pressure
1 bar 5 bar
Power supply – acceptable voltage ranges
Minimum Maximum
230 volt model 207 volts 253 volts
Warranty Information
The warranty statement for this product is provided
separately from this manual. Refer to it for
applicable coverage. In general warranty covers
defects in material or workmanship. It does not
cover maintenance, corrections to installations, or
situations when the machine is operated in
circumstances that exceed the limitations printed
above.
Product Information
The product is a self contained cuber with bin. That
type of machine is designed to be free standing or
it can be built in under the counter.
2007
Page 2
CU1526, CU2026, CU3030
Installation Manual
Air Flow
Room Temp Air In
Warm Air Out
Bekijk gratis de handleiding van Scotsman Prodigy CU1526, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Scotsman |
Model | Prodigy CU1526 |
Categorie | Niet gecategoriseerd |
Taal | Nederlands |
Grootte | 8139 MB |