HID312AWX, HID525AWX and HID540AWX
Installation and Users Manual
January 2025
Page 8
Installation - Electrical
Electrical Supply - 115 volt models
Plug the unit into a dedicated 15 amp outlet. The unit must be the only device on the circuit. Conrm the outlet
is properly grounded and is in good condition. Worn outlets should be replaced as they can cause erratic
operation of equipment. Do not use an extension cord. Do not cut o󰀨 the ground plug on the power cord.
Ground fault outlets are not recommended. If ground fault is required, a ground fault breaker should be used.
This ice machine should be installed on a dedicated circuit with a properly sized HACR-rated breaker or fuse.
No other devices or appliances should be connected to the same circuit with the ice machine. Installing a unit
on a shared circuit can cause product malfunctions or damage to the unit. The proper circuit size can be found
on the unit data tag listed as “MAX FUSE OR HACR TYPE CIRCUIT BREAKER”. Never allow the fuse size to
exceed the maximum fuse size listed on the data tag.
The use of a ground fault circuit interrupter (GFCI) or arc-fault circuit interrupter (ARCI) can lead to nuisance
trips and is not recommended for use on most appliances, including our equipment.
If local codes or other specications require the use of ground fault circuit interrupters, a properly rated HACR
GFCI or ARCI circuit breaker should be used. An outlet type GFCI or ARCI is not recommended for ice
machines and other refrigeration equipment due to more frequent nuisance trips of the GFCI or ARCI.
Always check with your local electrical inspector about the specic code requirements in your area for GFCI
or ARCI breakers and GFCI or ARCI receptacles. Use the services of a licensed electrician when needed and
conform to local and national codes.
Follow All Local Codes - This Unit Must Be Grounded. Do not use extension cords and do not disable or
by-pass ground prong on electrical plug.
Use the services of a licensed electrician when needed and conform to local and national codes.
Position the unit in its nal location.