Chart Definitions
•
Op Mode = The mode the controller was in at the time shown
•
Error Code = The codes, if any, of any diagnostic codes.
•
Warning = The codes, if any, of any warnings. Same codes as diagnostic
•
Pwr Interrupts = Number of electrical power interruptions to the machine
•
Time to Clean=0=no,1=yes
•
Button Lock=0=no,1=yes
•
Time to Clean Interval = Time set between Cleaning light activations, in hours.
•
Compressor Run = Time compressor has been operating
•
Pwr Up Time = Time power connected to machine.
•
Bin Level = Ice level measured by the ice level control
•
Bin Setpoint = Set point of the ice level control
•
Freeze Timer = time in seconds that the compressor operated before bin full
•
Board Voltage = approximation of AC voltage to the control board from the transformer
•
Relay Voltage = AC load voltage determined by controller. 115 or 230.
•
Auger Motor Current = amp draw of the auger motor x10
•
Ice Making Sensed=0=notsensed, 1 = sensed
•
Bin Stat = Bin thermostat, when used. 0 open, 1 closed.
•
RLO = SmartLock option. 0 not locked, 1 locked
•
Ice Dispensed - not used
•
Water Dispensed - not used
•
Compressor = 0 off, 1 on
• Auger = auger motor. 0 off, 1 on
•
Bin Eyes Blocked = 0=no, 1=yes