Scotsman CU0415X handleiding

52 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 17 van 52
January 2025
Page 15
User Manual for Models CU0415X, CU0715X and CU0920X
Only qualied technicians familiar with R290 refrig-
erant should decommission a machine, as special
tools and containers are required for the removal,
transportation, and disposal of this highly ammable
substance.
Before attempting the procedure:
* Ensure that all protective gear is present and
used throughout the procedure.
* Make sure recovery equipment and containers
are available and ready for use. All containers
used for recovery must be rated for R290
refrigerant and must be labeled as such.
* Weigh any refrigerant prior to reclaiming.
Maintain safety through standard operating proce-
dures as outlined on page 20 of this document. Be
sure to follow local, state, and federal guidelines
for proper disposal.
Do not ll containers more than 80% and do not
exceed the pressure limits of the container. Make
sure the machine to be decommissioned is in
satisfactory working order and that the electrical
components of the machine are properly sealed to
prevent ignition.
Recovered refrigerant should not be charged into
another refrigerating system or mixed in another
container.
Make sure to safely transport the refrigerant in line
with standard operating procedures.
All recovered refrigerant must be returned to re-
frigerant supplier for proper disposal.
If compressor or compressor oils are removed
ensure it has been removed to an acceptable level
so the ammable refrigerant does not remain in
the lubricant.
Decommissioning