Only use saw blades recommended by the manufac-
turer.
Saw blades designed to cut wood and similar materi-
als must comply with EN 847-1.
Only use saw blades for which the maximum permis-
sible speed is not lower than the maximum spindle
speed of the saw and which are suitable for the mate-
rial to be cut.
Observe the direction of rotation of the saw blade.
Only use saw blades if you have mastered their use.
Observe the maximum speed. The maximum speed
specified on the saw blade may not be exceeded. If
specified, observe the speed range.
Clean dirt, grease, oil and water off of the clamping
surfaces.
Do not use any loose reducing rings or bushes for the
reducing of holes on saw blades.
Make sure that fixed reducer rings for securing the
saw blade have the same diameter and have at least
1/3 of the cutting diameter.
Make sure that fixed reducer rings are parallel to each
other.
Handle saw blade with caution. They are ideally
stored in the originally package or special containers.
Wear protective gloves in order to improve grip and to
further reduce the risk of injury.
Prior to use, make sure that the saw blade meets the
technical requirements of this saw and is properly fas-
tened.
Only use the supplied saw blade for cutting wood,
never for the processing of metals.
Use only a saw blade with a diameter that matches
the specifications on the saw.
Use additional workpiece supports, if required for
workpiece stability.
Workpiece support extensions must always be se-
cured and used during work.
Replace table inlays when worn!
Avoid overheating the saw teeth.
When sawing plastic, avoid melting of the plastic.
Use the correct saw blades for the material to be cut.
Replace damaged or worn saw blades immediately.
When the saw blade overheats, stop the machine. Al-
low the saw blade to cool down before using the ma-
chine again.
Use only saw blades that are marked with an equal or
higher rotational speed than the rotational speed
specified on the electric tool.
Always ensure that the saw is stable and secure.
Safe work
Tools may only be used by trained and experienced per-
sons who are proficient in handling tools.
The maximum speed specified on the insertion tool
may not be exceeded. Where indicated, the speed
range must be observed.
Circular saw blades with cracks in the blade must be
discarded (repair is not permitted).
Tools with visible cracks must not be used.
Tools must be cleaned regularly.
Tool parts made of light alloys may only be cleaned,
e.g. of resin, with solvents that do not impair the me-
chanical properties of these materials.
1. Tools and tool bodies must be clamped in such a way
that they cannot come loose during operation.
2. Extending the key or tightening it with the help of ham-
mer blows is not permitted.
3. The clamping surfaces must be cleaned of dirt,
grease, oil and water.
4. Spare parts must comply with the specifications for
original parts supplied by the manufacturer.
5. Maintenance work and modifications to circular saw
blades should only be carried out by a competent per-
son, i.e. a person with specialist training and experi-
ence who is familiar with the requirements for con-
struction and design and who is familiar with the re-
quired safety levels.
Residual risks
The product has been built according to state-of-the-
art and the recognised technical safety rules.
However, individual residual risks can arise during
operation.
Damage to hearing if the stipulated hearing protection
is not worn.
Residual risks can be minimised if the "Safety Instruc-
tions" and the "Intended Use" together with the oper-
ating manual as a whole are observed.
Use the product in the way that is recommended in
this operating manual. This is how to ensure that your
product provides optimum performance.
Furthermore, despite all precautions having been met,
some non-obvious residual risks may still remain.
WARNING
This power tool generates an electromagnetic field
during operation. This field can impair active or passive
medical implants under certain circumstances. In order
to prevent the risk of serious or deadly injuries, we rec-
ommend that persons with medical implants consult
with their physician and the manufacturer of the medical
implant prior to operating the power tool.
6 Technical data
Nominal voltage 12V
Idle speed n
0
1450 rpm
Weight (without battery) approx. 1 kg
Max. cut depth
at 90° 26.5 mm
at 45° 17 mm
Saw blade
Dimensions Ø85 mm x Ø15 mm x 0.8 mm
Tooth thickness / cutting
thickness
1.1 mm
Size of hole Ø15 mm
Number of teeth 20 teeth
GB | 23www.scheppach.com

Bekijk gratis de handleiding van Scheppach C-HCS85-12/2, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkScheppach
ModelC-HCS85-12/2
CategorieNiet gecategoriseerd
TaalNederlands
Grootte6330 MB