Sauermann Si-CPE320 handleiding
Handleiding
Je bekijkt pagina 7 van 38

Introduction 7
3. Introduction
3.1 Description of the transmitter
3.1.1 Overall description
3
4
5
1
1 - Touch screen
2 - Access to device settings menu
3 - Software connection
4 - Transmitter power indicator
5 - Wireless connection indicator
6 - Front + pressure connector
7 - Front - pressure connector
8 - Probe connector
2
6
7
8
3.1.2 Screen description
2
1
3
4 5
1. Channel ID
2. Alarm pictogram
3. Trend indicator
4. Measured value
5. Unit of the measured value
Trend indicator: Trend indicator: on the screen, a trend indicator represented by a rising arrow, a going down arrow or a stable ar-
row is displayed on the left of the measurement unit. It means the calculation of a moving average on the last hour
(M1) to compare with a moving average on the last 5 minutes (M2):
• If M1 = M2, the trend is stable.
• If M1 < M2, the trend is upwards.
• If M1 > M2, the trend is downward.
This trend indicator is displayed after 5 minutes.
Alarm pictogram: on the screen, an alarm pictogram is displayed for each channel. Two different pictograms can
be displayed:
There is no alarm congured and activated for the channel