Depending on frequency of use, the motorised power head drive belt
will occasionally require changing.
1. Disconnect the power head from the telescopic tube.
2. Turn the power head upside down and turn the three locking rods
anti-clockwise to unlock the bottom plate.
3. Firstly lift the side of the rotating brush without the belt attached.
Then lift the end cap where the belt loops around.
4. Slide the old belt off the drive shaft and then
the end cap. If the belt is broken, remove all the broken pieces.
5. Place the new belt over the drive shaft first and then the end cap.
Make sure the lettering on the belt is outward facing. Insert the end
cap into the groove.
6. Holding the rotating brush, insert it into the end cap first and then
into the groove on the opposite side.
7. Replace the bottom plate.
Maintenance