Installation
English24
Dryer requirements
Ducting requirements
Weather hood type
Recommended
Use only for short-run
installation
102 mm 64 mm
No. of 90° elbows Rigid Rigid
0 24.4 m 22.6 m
1 20.7 m 18.9 m
2 17.4 m 15.5 m
3 14.3 m 12.5 m
NOTE
* Use a 102 mm diameter rigid aluminum or galvanized steel duct.
If you integrate the dryer’s vent system with an existing exhaust system:
Make sure the exhaust system meets all applicable local, state, and national regulations.
Verify you are not using flexible plastic duct.
Make sure to check for and remove all lint buildup from inside the existing ducts.
Confirm the duct is not kinked or crushed.
Make sure the exhaust hood damper opens and closes freely.
Manometer measurements
The static pressure in any exhaust system must not exceed 21 mm of water column or be less than 0. Note
that these values are measured with the dryer running with a manometer presented to the exhaust duct
that connects to the dryer. The dryer drum must be empty and lint filter clean.