Installation
5. Secure the water line to a sink or a wall
using a clip.
CAUTION
• Do not tighten the water line
excessively. Make sure the water line is
not bent, pinched, or squashed.
• Do not mount the water line on any
part of the refrigerator. This may
damage the refrigerator.
NOTE
If you have to relocate the refrigerator
after connecting the water line, make sure
the joined section of the water line must is
straight.
To repair the water line
CAUTION
The water line must be repaired by a qualied professional. If you encounter a water leak,
contact a local Samsung service centre or the installer of the water line.
Reverse osmosis water ltration system
The water pressure of the water supply system to a reverse osmosis water ltration
system must be between 206 kPa (30 psi) and 861 kPa (125 psi).
The water pressure of the reverse osmosis water ltration system to the refrigerator’s
cold water line must be at least 206 kPa (30 psi). If the water pressure is below the
specied:
• Check if the sediment lter in the reverse osmosis system is blocked. Replace the lter
if necessary.
• Rell the water tank in the reverse osmosis system with water.
• If your refrigerator has a water lter, it may further reduce the water pressure when
used in conjunction with a reverse osmosis system. Remove the water lter.
For more information or servicing, contact a licensed plumbing professional.
Ordering a new lter
To purchase a new water lter (part type: HAFEX/EXP), contact a local Samsung service
centre.