Installation requirements
English20
Exhausting requirements
The dryer must not be exhausted into a chimney, a wall, a ceiling, an attic, a crawl space, or a concealed
space of a building. Exhausting the dryer to the outside will prevent large amounts of lint and moisture
from being blown into the room.
In the United States and Canada
All dryers must be exhausted to the outside.
The required exhaust duct is 4 inches (10.2 cm) in diameter.
See “Ducting requirements in the “Installation” section for the maximum duct length and number of
bends that can be used.
The total length of flexible metal duct must not exceed 7’ 10 1/2” (2.4 m).
Do not assemble the duct with screws or other fasteners that extend into the duct and catch lint.
For the United States only: Use only those foil-type flexible ducts, if any, specifically identified for use
with the appliance by the manufacturer and that comply with the Outline for Clothes Dryer Transition
Duct. Use Subject 2158A.
Outside the United States and Canada
Refer to the local codes.
WARNING
You must exhaust the dryer to the outside to reduce the risk of fire when you install the dryer in an
alcove or closet.
Do not use a plastic or non-metal flexible duct.
If your existing ductwork is plastic, non-metal, or combustible, replace it with metal.
Use only a metal exhaust duct that is non-flammable to ensure containment of exhaust air, heat, and
lint.