Display Explanation Error Source
901 Water inlet (PHE) temperature sensor error(open/short) Hydro Unit
902 Water outlet (PHE) temperature sensor error(open/short) Hydro Unit
903 Water outlet (backup heater) temperature sensor error Hydro Unit
904 DHW tank temperature sensor error Hydro Unit
906 Refrigerant gas inlet (PHE) temperature sensor (open/short) Outdoor Unit
911
Low ow rate error
• in case of low ow rate in 30 sec during water pump signals is
ON(Starting)
• in case of low ow rate in 15 sec during water pump signals is ON(After
starting)
Hydro Unit
912
Normal ow rate error
• in case of normal ow rate in 10min during water pump signal is OFF
Hydro Unit
916 Mixing valve sensor error Hydro Unit
919
Error that the set temperature for disinfection operation is not reached, or,
after reaching, the temperature fails to continue for the requested time
Hydro Unit