Installation Procedure
Installation Procedure
Step 6 Connecting the refrigerant pipe
Items Maximum allowable length [ft(m)]
Applicable outdoor unit models
AC026BXADEH
AC035BXADEH
AC052BXADEH
AC071BXADEH
AC100BXADEH
AC100BXADGH
AC120BXADEH
AC120BXADGH
AC180BXADGH
Main pipe (L1) 20 30 50 75
Max. height difference between
outdoor and indoor units (h1)
15 20 30 30
n=1
h₁
indoor
outdoor
L₁
Temper grade and minimum thickness of the
refrigerant pipe
Outer diameter [mm] Minimum thickness [mm] Temper grade
ø6.35 0.7
C1220T-O
ø9.52 0.7
ø12.70 0.8
ø15.88 1.0
ø15.88 0.8
C1220T-1/2H OR
C1220T-H
ø19.05 0.9
ø22.23 0.9
CAUTION
Be sure to use C1220T-1/2H (Semi-hard) pipe for more than
Ø19.05 mm. If you use C1220T-O (Soft) pipe for Ø19.05 mm,
the pipe may burst open, which can result in an injury.
AC026/035/052/071BXADEH
Make at least one round:
It will reduce noise and
vibration
AC100/120BXADEH & AC100/120/180BXADGH
After
connectiong
the pipes, block
the part .
Make at least one round:
It will reduce noise and vibration
(A) Heat radiation holes
Do not block the holes.
The designs and shape are subject to change according
to the model.
CAUTION
Pipe outlet
Cut the pipe outlet to the exact pipe size. In addition,
remove foreign substances and burres aroud the outlet.
Perform cutting with only a cutter (ex. nipper)and
never tap with a hammer near the pipe outlet.
Otherwise, it may cause product damage such as
warping of the cabinet.
After connecting the pipes with Pipe outlet, plug the
space around the pipes.
After connecting the pipes, proceed exactly as directed
in the guide to prevent interference with the internal
parts.
Tighten the nuts to the specified torques. If
overtightened, the nuts could be broken so refrigerant
may leak.