Safety Information
Safety Information
Installing the unit
WARNING
IMPORTANT: When installing the unit, always remember to
connect first the refrigerant tubes, then the electrical lines.
• Upon receipt, inspect the product to verify that it has
not been damaged during transport. If the product
appears damaged, DO NOT INSTALL it and immediately
report the damage to the carrier or retailer (if the
installer or the authorized technician has collected the
material from the retailer.)
• After completing the installation, always carry out a
functional test and provide the instructions on how to
operate the air conditioner to the user.
• Do not use the air conditioner in environments with
hazardous substances or close to equipment that
release free flames to avoid the occurrence of fires,
explosions or injuries.
• Our units should be installed in compliance with the
spaces shown in the installation manual, to ensure
accessibility from both sides and allow repairs or
maintenance operations to be carried out. The
unit’s components should be accessible and easy to
disassemble without endangering people and objects.
• For this reason, when provisions of the installation
manual are not complied with, the cost required to
access and repair the units (in SAFETY CONDITIONS,
as set out in prevailing regulations) with harnesses,
ladders, scaffolding or any other elevation system will
NOT be considered part of the warranty and will be
charged to the end customer.
• The outdoor unit shall be installed in an open space that
is always ventilated.
• The local gas regulations shall be observed.
• To handle, purge, and dispose the refrigerant, or break
into the refrigerant circuit, the worker should have a
certificate from an industry-accredited authority.
• While in installation or relocation of the product, do
not mix the refrigerant with other gases including air
or unspecified refrigerant. Failure to do so may cause
pressure increase to result in rupture or injury.
• Do not cut or burn the refrigerant container or pipings.
• Use clean parts such as manifold gauge, vacuum pump,
and charging hose for the refrigerant.
• Installation must be carried out by qualified personnel
for handling the refrigerant. Additionally, reference the
regulations and laws.
• Be careful not to let foreign substances (lubricating oil,
refrigerant, water, etc.) enter the pipings.
• When mechanical ventilation is required, ventilation
openings shall be kept clear of obstruction.
• For disposal of the product, follow the local laws and
regulations.
• Do not work in a confined place.
• The work area shall be blocked.
• The refrigerant pipings shall be installed in the position
where there are no substances that may result in
corrosion.
• The following checks shall be performed for installation:
– The charging amount depends on the room size.
– The ventilation devices and outlets are operating
normally and are not obstructed.
– Markings and signs on the equipment shall be
visible and legible.
• Upon leakage of the refrigerant, ventilate the room.
When the leaked refrigerant is exposed to flame, it may
cause generation of toxic gases.
• Make sure that the work area is safe from flammable
substances.
• To purge air in the refrigerant, be sure to use a vacuum
pump.
• Note that the refrigerant has no odour.
• The units are not explosion proof so they must be
installed with no risk of explosion.
• This product contains fluorinated gases that contribute
to global greenhouse effect. Accordingly, do not vent
gases into the atmosphere.
• For installation with handling the refrigerant(R-32), use
dedicated tools and piping materials. Working pressure
of R-32 is higher than R410A, So failure to use the
dedicated tools and piping materials may cause rupture
or injury. Furthermore, it may cause serious accidents
such as water leakage, electric shock or fire.
• Servicing shall be performed as recommended by the
manufacturer. In case other skilled persons are joined
for servicing, it shall be carried out under supervision
of the person who is competent in handling flammable
refrigerants.