18
Cleaning and Maintaining
English
Cleaning and Maintenance
Periodical maintenance
If the air conditioner will not be used for an extended period of time, dry the air conditioner to maintain in
best conditions.
1. Dry the air conditioner thoroughly by operating in Fan mode for 3 to 4 hours and disconnect the power
plug. There may be internal damage if moisture is left in components.
2. Before using the air conditioner again, dry the inner components of the air conditioner again by running
in Fan mode for 3 to 4 hours. This helps remove odours that may have generated from dampness.
Periodical checks
Refer to the following chart to maintain the air conditioner properly.
Unit Maintenance item Interval
Requires qualified
technicians
Indoor unit
Clean the air filter. At least once a month
Clean the condensate drain pan. Once a year Required
Clean up the heat exchange. Once a year Required
Clean the condensate drain pipe. Once every 4 months Required
Replace the remote control batteries. At least once a year
Outdoor unit
Clean the heat exchanger. Once every 3 months Required
Clean the electric components with jets
of air.
Once a year Required
Verify that all the electric components are
firmly tightened.
Once a year Required
Clean the fan. Once a year Required
Verify that the fan assemblies are firmly
tightened.
Once a year Required
Clean the condensate drain pan. Once a year Required