Handleiding
Je bekijkt pagina 18 van 38

18
Connecting the cable
Connecting the Power Terminal
Connect the cables to the terminal board using the compressed ring terminal.
Cover a solderless ring terminal and a connector part of the power cable and then connect it.
Silver solder
Nominal
dimensions
for cable
[mm
2
(inch
2
)]
Nominal
dimensions
for screw
[mm(inch)]
B D d1 E F L d2 t
Standard
dimension
[mm(inch)]
Allowance
[mm(inch)]
Standard
dimension
[mm(inch)]
Allowance
[mm(inch)]
Standard
dimension
[mm(inch)]
Allowance
[mm(inch)]
Min.
[mm
(inch)]
Min.
[mm
(inch)]
Max.
[mm
(inch)]
Standard
dimension
[mm(inch)]
Allowance
[mm(inch)]
Min.
[mm
(inch)]
4/6
(0.006/ 0.009)
4(3/8) 9.5(3/8)
±0.2
(±0.007)
5.6(1/4)
+0.3(+0.011)
-0.2(-0.007)
3.4(1/8)
±0.2
(±0.007)
6 (1/4)
5 (3/16) 20 (3/4) 4.3 (3/16)
+0.2 (+0.007)
0(0)
0.9
(0.03)
8(3/16) 15(9/16) 9 (3/8)
28.5 (1-
1/8)
8.4 (1-3/16)
+0.4 (+0.015)
0(0)
10(0.01) 8(3/16) 15(9/16)
±0.2
(±0.007)
7.1(1/4)
+0.3(+0.011)
-0.2(-0.007)
4.5(3/16)
±0.2
(±0.007)
7.9
(5/16)
9 (3/8)
30
(1-3/16)
8.4 (1-3/16)
+0.4 (+0.015)
0(0)
1.15
(0.04)
16(0.02) 8(3/16) 16(10/16)
±0.2
(±0.007)
9(3/8)
+0.3(+0.011)
-0.2(-0.007)
5.8(1/4)
±0.2
(±0.007)
9.5
(5/16)
13 (1/2)
33
(1-5/16)
8.4 (1-3/16)
+0.4
(+0.015) 0(0)
1.45
(0.05)
25(0.03)
8(3/16) 12(1/2)
±0.3
(±0.011)
11.5(7/16)
+0.5(+0.019)
-0.2(-0.007)
7.7(5/16)
±0.2
(±0.007)
11 (3/8)
15 (5/8)
34 (1-
3/8)
8.4 (1-3/16)
+0.4 (+0.015)
0(0)
1.7
(0.06)
8(3/16) 16.5(10/16) 13 (1/2) 8.4 (1-3/16)
35(0.05)
8(3/16) 16(10/16)
±0.3
(±0.011)
13.3(1/2)
+0.5(+0.019)
-0.2(-0.007)
9.4(3/8)
±0.2
(±0.007)
12.5
(1/2)
13 (1/2)
38 (1-
1/2)
8.4 (1-3/16)
+0.4 (+0.015)
0(0)
1.8
(0.07)
8(3/16) 22(7/8) 13 (1/2)
43 (1-
11/16)
8.4 (1-3/16)
50(0.07) 8(3/16) 22(7/8)
±0.3
(±0.011)
13.5(1/2)
+0.5(+0.019)
-0.2(-0.007)
11.4(7/16)
±0.3
(±0.011)
17.5
(11/16)
14
(9/16)
50 (2) 8.4 (1-3/16)
+ 0.4(+0.015)
0(0)
1.8
(0.07)
70(0.10) 8(3/16) 24(1)
±0.4
(±0.015)
17.5(11/16)
+0.5(+0.019)
-0.4(-0.015)
13.3(1/2)
±0.4
(±0.015)
18.5
(3/4)
20 (3/4) 51 (2) 8.4 (1-3/16)
+ 0.4(+0.015)
0(0)
2.0
(0.078)
Connect rated cables only.
Connect using a driver which is able to apply the rated torque to the screws.
If the terminal is loose, re may occur caused by arc. If the terminal is connected too rmly, the terminal may be
damaged.
Tightening Torque (lbf • ft)
M4
0.87~1.08 Communication : F1, F2
M5
1.45 ~ 2.17 1phase AC power : L1, L2
• When connecting cables, you can connect the cables to the electrical part or connect them through the holes
below depending on the spot.
• Run transmission wiring between the indoor and outdoor units through a conduit to protect against
external forces, and feed the conduit through the wall together with refrigerant piping.
• Remove all burrs at the edge of the knock-out hole and secure the cable to the outdoor knock-out using lining
and bushing with an electrical insulation such as a rubber bushing, etc.
• Must keep the cable in a protection tube.
• Keep distances of 1.97 in. or more between power cable and communication cable.
• When the cables are connected through the hole, remove the Plate bottom.
CAUTION
CAC 저온향 과제 북미향 실외기IM_EN_DB68-07245A-00.indd 18 2017-05-10 오후 2:52:55
Bekijk gratis de handleiding van Samsung AC036MXSCCC, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Samsung |
Model | AC036MXSCCC |
Categorie | Airco |
Taal | Nederlands |
Grootte | 4146 MB |