Installation Procedure
1) SEG4
By SEG4 setting, Minimizing fan operation when thermostat is off.
Fan stops or operates Ultra low in Cooling when thermostat is off.
2) SEG6
If you set the value to 0, ‘Standard installation’ mode is activated. If you set it to 1, ‘High-ceiling’ mode is activated.
Model name
Supported installation height
Standard installation mode (Disuse: 0) High-ceiling mode (Compensate for RPM: 1)
AC140FE4DKF/EA, AC160FE4DKF/EA 5.5m↓ Options cannot be set
AC100FE4DKF/EA, AC120FE4DKF/EA 3.2m↓ 4.2m↓
AC052FE4DKF/EA, AC071FE4DKF/EA 2.7m 3.5m↓
3) SEG8
Drain pump: The Drain pump option is automatically set to [Used with 3minute delay], even if you set it to [Disuse].
Emergency Stop: If you set Emergency Stop to [Use], it is not possible to use the ETO or On/Off Control feature through
External Control (SEG14).
4) SEG18
If you set the Maximum filter usage time option to a value other than 2 and 6, it is automatically set to 2 (1000 hours).
When a purification panel is used, the time in parentheses is used.
5) SEG20
If you set the Individual control with remote control option to a value other than 0 to 4, it is automatically set to 0 (Indoor 1)
6) SEG21
1WAY CST is set to 2 ℃ and 4WAY CST is set to 5 ℃, even if ‘0’ is selected.
7) SEG23
Soft Off: The indoor unit turns off its operation at the indicated time in the table for Installation Option after its final motion
detection. But, it turns on again if the MDS detects motion.
Hard Off: Designated time after SOFT OFF, it cannot turn on automatically when it detects motion. Users should control to
turn on the indoor unit with remote control, etc.
Changing the addresses and options individually
When you want to change the value of a specific option, refer to the following table and follow the steps in Common steps for
setting the addresses and options on page 33.
Option SEG1 SEG2 SEG3 SEG4 SEG5 SEG6
Function Page Mode Option mode to change
Tens position of the
option number
Units position of the
option number
New value
Indication
and details
Indication Details Indication Details Indication Details Indication Details Indication Details Indication Details
0 D
Option
type
0 to F
Tens
position
value
0 to 9
Units
position
value
0 to 9 New value 0 to F
Example: Changing the Buzzer control (SEG17) option of the installation options to 1 disuse.
Option SEG1 SEG2 SEG3 SEG4 SEG5 SEG6
Function Page Mode Option mode to change
Tens position of the
option number
Units position of the
option number
New value
Indication 0 D 2 1 7 1