Handleiding
Je bekijkt pagina 19 van 38

02 INSTALLATION
19
English
Connecting the Power Terminal
f Connect the cables to the terminal board using the compressed ring terminal.
f Cover a solderless ring terminal and a connector part of the power cable and then connect it.
Silver solder
Nominal
dimensions
for cable
[mm
2
(inch
2
)]
Nominal
dimensions
for screw
[mm(inch)]
BDd1EFLd2t
Standard
dimension
[mm(inch)]
Allowance
[mm(inch)]
Standard
dimension
[mm(inch)]
Allowance
[mm(inch)]
Standard
dimension
[mm(inch)]
Allowance
[mm(inch)]
Min.
[mm
(inch)]
Min.
[mm
(inch)]
Max.
[mm
(inch)]
Standard
dimension
[mm(inch)]
Allowance
[mm(inch)]
Min.
[mm
(inch)]
4/6
(0.006/
0.009)
4(3/8) 9.5(3/8)
±0.2
(±0.007)
5.6(1/4)
+0.3(+0.011)
-0.2(-0.007)
3.4(1/8)
±0.2
(±0.007)
6
(1/4)
5
(3/16)
20
(3/4)
4.3
(3/16)
+ 0.2(+0.007)
0(0)
0.9
(0.03)
8(3/16) 15(9/16)
9
(3/8)
28.5
(1-1/8)
8.4
(1-3/16)
+ 0.4(+0.015)
0(0)
10(0.01) 8(3/16) 15(9/16)
±0.2
(±0.007)
7.1(1/4)
+0.3(+0.011)
-0.2(-0.007)
4.5(3/16)
±0.2
(±0.007)
7.9
(5/16)
9
(3/8)
30
(1-3/16)
8.4
(1-3/16)
+ 0.4(+0.015)
0(0)
1.15
(0.04)
16(0.02) 8(3/16) 16(10/16)
±0.2
(±0.007)
9(3/8)
+0.3(+0.011)
-0.2(-0.007)
5.8(1/4)
±0.2
(±0.007)
9.5
(5/16)
13
(1/2)
33
(1-5/16)
8.4
(1-3/16)
+ 0.4(+0.015)
0(0)
1.45
(0.05)
25(0.03)
8(3/16) 12(1/2)
±0.3
(±0.011)
11.5(7/16)
+0.5(+0.019)
-0.2(-0.007)
7.7(5/16)
±0.2
(±0.007)
11
(3/8)
15
(5/8)
34
(1-3/8)
8.4
(1-3/16)
+ 0.4(+0.015)
0(0)
1.7
(0.06)
8(3/16) 16.5(10/16)
13
(1/2)
8.4
(1-3/16)
35(0.05)
8(3/16) 16(10/16)
±0.3
(±0.011)
13.3(1/2)
+0.5(+0.019)
-0.2(-0.007)
9.4(3/8)
±0.2
(±0.007)
12.5
(1/2)
13
(1/2)
38
(1-1/2)
8.4
(1-3/16)
+ 0.4(+0.015)
0(0)
1.8
(0.07)
8(3/16) 22(7/8)
13
(1/2)
43
(1-
11/16)
8.4
(1-3/16)
50(0.07) 8(3/16) 22(7/8)
±0.3
(±0.011)
13.5(1/2)
+0.5(+0.019)
-0.2(-0.007)
11.4(7/16)
±0.3
(±0.011)
17.5
(11/16)
14
(9/16)
50
(2)
8.4
(1-3/16)
+ 0.4(+0.015)
0(0)
1.8
(0.07)
70(0.10) 8(3/16) 24(1)
±0.4
(±0.015)
17.5(11/16)
+0.5(+0.019)
-0.4(-0.015)
13.3(1/2)
±0.4
(±0.015)
18.5
(3/4)
20
(3/4)
51
(2)
8.4
(1-3/16)
+ 0.4(+0.015)
0(0)
2.0
(0.078)
f Connect the rated cables only.
f Connect using a driver which is able to apply the rated torque to the screws.
f If the terminal is loose, re may occur caused by arc. If the terminal is connected too rmly, the terminal may be damaged.
Tightening Torque (kgf • cm) Model
M4 12.0~18.0
Communication : F1, F2 All model
1 phase AC power : 1(L), 2(N), L, N
AC018MXQFEC
AC024MXQFEC
3phase AC power : 1(L), 2(N), L1R, L2(S), L3(T), N AC048MXQFGC
M5 20.0~30.0 1 phase AC power : 1(L), 2(N), L, N
AC030MXQFEC
AC036MXQFEC
• When connecting cables, you can connect the cables to the electrical part or connect them through the holes
below depending on the spot.
• Run transmission wiring between the indoor and outdoor units through a conduit to protect against
external forces, and feed the conduit through the wall together with rergerant piping.
• Remove all burrs at the edge of the knock-out hole and secure the cable to the outdoor knock-out using lining
and bushing with an electrical insulation such as rubber and so on.
• Must keep the cable in a protection tube.
• Keep distances of 50mm or more between power cable and communication cable.
• When the cables are connected through the hole, remove the Plate bottom.
CAUTION
Bekijk gratis de handleiding van Samsung AC030MXQFEC, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Samsung |
Model | AC030MXQFEC |
Categorie | Airco |
Taal | Nederlands |
Grootte | 4327 MB |