Samsung AC024TXQREH handleiding

34 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 17 van 34
17
English
Installation Procedure
Outdoor-to-indoor power terminal specifications
Connect the cables to the terminal board using the compressed ring terminal.
Cover a solderless ring terminal and a connector part of the power cable and then connect it.
d2
F
L
E
B
d1
D
t
Silver solder
Norminal
dimensions
for cable
(mm²)
Norminal
dimensions
for screw
(mm)
BDd1EFLd2t
Standard
dimension
(mm)
Allowance
(mm)
Standard
dimension
(mm)
Allowance
(mm)
Standard
dimension
(mm)
Allowance
(mm)
Min.
(mm)
Min.
(mm)
Max.
(mm)
Standard
dimension
(mm)
Allowance
(mm)
Min.
(mm)
4/6
49.5
±0.2 5.6
+0.3
-0.2
3.4 ±0.2 6.0
520.0 4.3
+0.2
0
0.9
815.0 928.58.4
+0.4
0
10 8 15.0 ±0.2 7.1
+0.3
-0.2
4.5 ±0.2 7.9 9 30.0 8.4
+0.4
0
1.15
16 8 16.0 ±0.2 9.0
+0.3
-0.2
5.8 ±0.2 9.5 13 33 .0 8.4
+0.4
0
1.45
25
812.0
±0.3 11.5
+0.5
-0.2
7.7 ±0.2 11.0
15
34.0
8.4
+0.4
0
1.7
816.5 13 8.4
35
816.0
±0.3 13.3
+0.5
-0.2
9.4 ±0.2 12.5
13 38.0 8.4
+0.4
0
1.8
822.0 1343.08.4
50 8 22.0 ±0.3 13.5
+0.5
-0.2
11.4 ±0.3 17.5 14 50.0 8.4
+ 0.4
0
1.8
70 8 24.0 ±0.4 17.5
+0.5
-0.4
13.3 ±0.4 18.5 20 51.0 8.4
+ 0.4
0
2.0
Connect the rated cables only.
Connect using a driver which is able to apply the rated torque to the screws.
If the terminal is loose, fire may occur caused by arc. If the terminal is connected too firmly, the terminal may be damaged.
Ɵ˝˵ϩʪ˝ϩͱθαЇʪ࣍˝˙ଗʀ
M4 12.0 to 18.0
M5 20.0 to 30.0
ߢĘଗߢߡ˝˙ଗʀ
CAUTION
When connecting cables, you can connect the cables to the electrical part or connect them through the holes below
depending on the spot.
Connect the communication cable between the indoor and outdoor units through a conduit to protect against
external forces, and feed the conduit through the wall together with refrigerant piping.
Remove all burrs at the edge of the knock-out hole and secure the cable to the outdoor knock-out using lining and
bushing with an electrical insulation such as rubber and so on.
Must keep the cable in a protection tube.
Keep distances of 50mm or more between power cable and communication cable.
When the cables are connected through the hole, remove the Plate bottom.
ki]_TW`ZZ`hTWYptwhjG⴬⢰㫴G㐘㞬ὤG㢨㬅䏬䑀䇘㏘䇸pxluUGGGX^ YWYWTXYTW`GGG㝘㤸GXXa[`a[W

Bekijk gratis de handleiding van Samsung AC024TXQREH, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkSamsung
ModelAC024TXQREH
CategorieAirco
TaalNederlands
Grootte5383 MB