Samsung AC024MNADCH handleiding

62 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 35 van 62
35English
Appendix
The table below indicates the temperature and humidity ranges the air conditioner can be
operated within. Refer to the table for efficient use.
AC

MN
DCH / AC

XCDCH
MODE OUTDOOR TEMPERATURE INDOOR TEMPERATURE INDOOR HUMIDITY
COOLING
-18 ˚C to 46 ˚C
(0 ˚F to 115 ˚F)
18 ˚C to 32 ˚C
(64 ˚F to 90 ˚F)
80 % or less
HEATING
-20 ˚C to 24 ˚C
(-4 ˚F to 75 ˚F)
30 ˚C (86 ˚F) or less -
DRYING
-18 ˚C to 46 ˚C
(0 ˚F to 115 ˚F)
18 ˚C to 32 ˚C
(64 ˚F to 90 ˚F)
80 % or less
AC

MN
DCH / AC

MXSCCC
MODE OUTDOOR TEMPERATURE INDOOR TEMPERATURE INDOOR HUMIDITY
COOLING
-40 ˚C to 46 ˚C
(-40 ˚F to 115 ˚F)
18 ˚C to 32 ˚C
(64 ˚F to 90 ˚F)
80 % or less
DRYING
-40 ˚C to 46 ˚C
(-40 ˚F to 115 ˚F)
18 ˚C to 32 ˚C
(64 ˚F to 90 ˚F)
80 % or less
CAUTION
• If the indoor unit is installed in an IT room (for example,
computer room), a separate back-up system must be installed,
and the reliability of our product cannot be guaranteed under
conditions of -40 °C (-40 °F) or less.
NOTE
• The standardized temperature for heating is 8.3 ˚C (47 ˚F). If the outdoor temperature drops
to 0 ˚C (32 ˚F) or below, the heating capacity can be reduced depending on the temperature
condition.
• If the cooling operation is used at over 32˚C (90 ˚F) (indoor temperature), it does not cool at
its full capacity.
Operation Ranges