Installation Procedure
English
Installation Procedure
Connecting wire conduits
When connecting cables between the indoor unit and the
outdoor unit, use conduits to protect the cables.
1 Drill holes on the conduit plate in accordance with
their use and quantity.
• AC018BXADCH, AC018/024BXSCCC
– Drill conduit holes on the side cabinet. (knock
out holes)
Conduit Holes
• AC024/030/036/042/048BXADCH,
AC030/036BXSCCC, AC030/036BXSCCH
– Use a nipper to remove conduit holes from the
lower part of the cabinet.
(Do not remove it by hammering.)
Conduit Holes
2 Insert the cables through the conduits, and then fix the
conduits to the conduit plate with the lock nuts.
3 Apply silicone to the end of the hose to prevent rain
from entering the hose.
Silicone
Conduit inserted into the outdoor unit
4 Connect the cables to the outdoor units.
For how to connect the cables, refer to the next page.
5 Attach the conduit plate to the product.
Air conditioning system examples
When using earth leakage circuit breaker (ELCB) for a
single phase
Communication cable
Indoor Unit
Main power
cable
MCCB
1
Outdoor-to-indoor power cable
Outdoor Unit
Earthing
ELB
ELCB
1
OR
࢘Ɵ˵ʪɇΧΧʪɇθɇʀʪͱ˙ϩ˵ʪЇϩɇцɵʪʒ˙˙ʪθʪϩ˙θͱϩ˵ʪ
picture depending on the model.
CAUTION
• If the outdoor unit is installed in a location vulnerable
to an electric leak or submergence, make sure to
install an ELCB.
• AC018/024BXADCH, AC030/036BXSCCH: ELCB must
be installed since this product is equipped with a base
heater.
ki]_TXXY^[hTWZptjhjG|GvhhluUGGGXW YWYYTW_TYZGGG㝘㤸G_a[XaX]