Installation Procedure
Single phase
Model Outdoor unit Input current (Amperes) Power supply
Indoor unit Outdoor unit
Rated Voltage range Outdoor unit
Indoor
unit
Total MCA MFA
Hz Volts Min. Max.
Cooling Heating
AC012TNMPEC AC012TXQLEC
50 220-240 198 264
10.0 - 2.5 12.5 12.5 13.8
NOTE
1 Voltagerange
Unitsaresuitableforuseonelectricalsystemswherevoltagesuppliedtounitterminalisnotbelowor
abovelistedrangelimits
2 Maximumallowablevoltagevariationbetweenphasesis2%.
3 Wiresize&typemustcomplywiththeapplicablelocalandnationalcode.
Wiresize:BasedonthevalueofMCA.
Wiretype:
1-phase:60245IEC57(IEC)orH05RN-F(CENELEC)gradeormore
4 MFAisusedtoselectthecircuitbreakerandthegroundfaultcircuitinterrupter(earthleakagecircuit
breaker).
5 MCArepresentsmaximuminputcurrent.
MFArepresentscapacitywhichmayacceptMCA
Abbreviations
MCA:Min.CircuitAmps.(A)
MFA:Max.FuseAmps.(A)