Saivod ASCT1224 handleiding

149 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 141 van 149
Cooling Y Average (mandatory) Y
Heating Y
Warmer (if
designated)
Y
Colder (if
designated)
Y
Item
symbol
value
unit
item
symbol
value
unit
Cooling
Pdesignc
5.1
kW
Cooling
SEER
6.1
Heating/Average
Pdesignh
3.8
kW
Heating/Average
SCOP/A
4.0
Heating/Warmer
Pdesignh
5.0
kW
Heating/Warmer
SCOP/W
5.1
Heating/Colder
Pdesignh
4.0
kW
Heating/Colder
SCOP/C
3.4
Tj = 35 °C
Pdc
5.10
kW
Tj = 35 °C
EERd
3.38
Tj = 30 °C
Pdc
3.62
kW
Tj = 30 °C
EERd
4.80
Tj = 25 °C
Pdc
2.84
kW
Tj = 25 °C
EERd
7.65
Tj = 20 °C
Pdc
1.81
kW
Tj = 20 °C
EERd
10.94
Tj = – 7 °C
Pdh
3.36
kW
Tj = – 7 °C
COPd
2.78
Tj = 2 °C
Pdh
2.15
kW
Tj = 2 °C
COPd
4.01
Tj = 7 °C
Pdh
1.38
kW
Tj = 7 °C
COPd
5.07
Tj = 12 °C
Pdh
1.32
kW
Tj = 12 °C
COPd
6.38
Tj = bivalent
temperature
Pdh
3.36
kW
Tj = bivalent
temperature
COPd
2.78
Tj = operating limit (-
15 °C)
Pdh
4.42
kW
Tj = operating limit (-
15 °C)
COPd
2.46
Tj = 2 °C
Pdh
5.01
kW
Tj = 2 °C
COPd
2.84
Tj = 7 °C
Pdh
3.31
kW
Tj = 7 °C
COPd
4.74
Tj = 12 °C
Pdh
1.61
kW
Tj = 12 °C
COPd
6.44
Tj = bivalent
temperature
Pdh
5.01
kW
Tj = bivalent
temperature
COPd
2.84
Tj = operating limit Pdh
5.01
kW Tj = operating limit COPd
2.84
Tj = – 7 °C
Pdh
2.39
kW
Tj = – 7 °C
COPd
2.82
Tj = 2 °C
Pdh
1.61
kW
Tj = 2 °C
COPd
4.26
Tj = 7 °C
Pdh
1.05
kW
Tj = 7 °C
COPd
5.03
Tj = 12 °C
Pdh
1.32
kW
Tj = 12 °C
COPd
6.75
Tj = bivalent
temperature
Pdh
3.27
kW
Tj = bivalent
temperature
COPd
1.95
Tj = operating limit Pdh
3.12
kW Tj = operating limit COPd
2.01
Tj = -15 °C
Pdh
3.27
kW
Tj = -15 °C
COPd
1.95
Function (indicate if present)
If function includes heating: Indicate the heating season the information
relates to. Indicated values should relate to one heating season at a time.
Include at least the heating season 'Average'.
ASCT1824
Declared capacity (*) for heating/Average season, at indoor
temperature 20 °C and outdoor temperature Tj
Declared coefficient of performance (*)/Average season, at indoor
temperature 20 °C and outdoor temperature Tj
Declared capacity (*) for cooling, at indoor temperature
27(19) °C and outdoor temperature Tj
Declared energy efficiency ratio (*), at indoor temperature 27(19) °C and
outdoor temperature Tj
Seasonal efficiencyDesign load
Declared capacity (*) for heating/Colder season, at indoor
temperature 20 °C and outdoor temperature Tj
Declared coefficient of performance (*)/Colder season, at indoor temperature
20 °C and outdoor temperature Tj
Declared capacity (*) for heating/Warmer season, at indoor
temperature 20 °C and outdoor temperature Tj
Declared coefficient of performance (*)/Warmer season, at indoor
temperature 20 °C and outdoor temperature Tj