cooling Y Average
(mandatory)
Y
heating Y Warmer
(if designated)
Y
Colder
(if designated)
N
Item
symbol
value
unit
Item
symbol
value
unit
Design load
Seasonal efficiency
cooling
Pdesignc
3.400
kW
cooling
SEER
6.10
heating/Average
Pdesignh
2.100
kW
heating/Average
SCOP/A
4.00
heating/Warmer
Pdesignh
2.400
kW
heating/Warmer
SCOP/W
5.10
heating/Colder
Pdesignh
N/A
kW
heating/Colder
SCOP/C
N/A
Tj = 35 °C
Pdc
3.400
kW
Tj = 35 °C
EERd
2.92
Tj = 30 °C
Pdc
2.340
kW
Tj = 30 °C
EERd
4.75
Tj = 25 °C
Pdc
1.490
kW
Tj = 25 °C
EERd
8.00
Tj = 20 °C
Pdc
0.860
kW
Tj = 20 °C
EERd
11.30
Tj = – 7 °C
Pdh
1.860
kW
Tj = – 7 °C
COPd
2.620
Tj = 2 °C
Pdh
1.190
kW
Tj = 2 °C
COPd
4.110
Tj = 7 °C
Pdh
0.790
kW
Tj = 7 °C
COPd
5.050
Tj = 12 °C
Pdh
0.770
kW
Tj = 12 °C
COPd
5.870
Tj = bivalent
temperature,- 7 °C
Pdh
1.860
kW Tj = bivalent
temperature
COPd
2.620
Tj = operating limit, -
15°C
Pdh
2.080
kW Tj = operating
limit
COPd
2.420
Tj = 2 °C Pdh
2.400
kW Tj = 2 °C COPd
3.080
Tj = 7 °C Pdh
1.550
kW Tj = 7 °C COPd
5.150
Tj = 12 °C Pdh
0.770
kW Tj = 12 °C COPd
5.940
Tj = bivalent
temperature
Pdh
2.400
kW Tj = bivalent
temperature
COPd
3.080
Tj = operating limit Pdh
2.400
EN 14511:
2013+ EN
14825:
2016
Tj = operating
limit
COPd
3.080
Tj = – 7 °C
Pdh
N/A
kW
Tj = – 7 °C
COPd
N/A
Tj = 2 °C
Pdh
N/A
kW
Tj = 2 °C
COPd
N/A
Tj = 7 °C
Pdh
N/A
kW
Tj = 7 °C
COPd
N/A
Tj = 12 °C
Pdh
N/A
kW
Tj = 12 °C
COPd
N/A
Tj = bivalent
temperature
Pdh N/A kW Tj = bivalent
temperature
COPd N/A
Tj = operating limit Pdh N/A kW Tj = operating
limit
COPd N/A
Tj = – 15 °C
Pdh
N/A
kW
Tj = – 15 °C
COPd
N/A
ASCT1224
Declared capacity (*) for heating/Average season, at indoor
temperature 20°C and outdoor temperature Tj
Declared coefficient of performance (*)/Average season, at
indoor temperature 20°C and outdoor temperature Tj
Declared energy efficiency ratio (*), at indoor temperature
27(19) °C and outdoor temperature Tj
Declared capacity (*) for cooling, at indoor temperature 27(19) °C
and outdoor temperature Tj
If function includes heating: Indicate the heating season the
information relates to. Indicated values should relate to one
heating season at a time.
Include at least the heating season 'Average'.
Function (indicate if present)
Declared coefficient of performance (*)/Colder season, at
indoor temperature 20°C and outdoor temperature Tj
Declared capacity (*) for heating/Colder season, at indoor
temperature 20°C and outdoor temperature Tj
Declared coefficient of performance (*)/Warmer season, at
indoor temperature 20°C and outdoor temperature Tj
Declared capacity (*) for heating/Warmer season, at indoor
temperature 20°C and outdoor temperature Tj