Saba OMP7324BL/A handleiding

59 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 37 van 59
fixed wiring.
Connect the incoming positive, neutral and earth cables to
the terminals of the switched fused connection unit. Ensure
connections are tight.
The spur outlet must still be accessible even when your oven
is located in its housing to enable the appliance to be
disconnected from the mains supply.
Cleaning
Always disconnect the power supply prior to cleaning the
appliance. If the switched fused connection unit is difficult to
reach, shut off the power supply by using the corresponding
circuit breaker at the distribution board.
Clean the appliance thoroughly before first use. The oven
should be cleaned regularly and any food deposits removed.
Never clean the oven surfaces by steam cleaning.
The oven cavity should only be cleaned with warm soapy
water, using either a sponge or soft cloth. No abrasive
cleaners should be used.
Any stains that may appear on the bottom of the oven will
have originated from food splashes or spilt food, these
splashes occur during the cooking process. These could
possibly be a result of the food being cooked at an excessively
high temperature or being placed in cookware that is too
small.
1. INTRODUCTION
Read this manual carefully before assembling, installing or
using the appliance. It contains important information for your
safety as well as operating and maintenance advices.
Observe all safety instructions to avoid damage through
improper assembly, installation or use! Follow all warnings on
the appliance.
Keep this manual for future use.
Danger of electric shock!
Any electrical installation must be carried out by an authorised
professional.
All fittings must be installed by a competent person in
accordance with local regulations. If in doubt, consult a
qualified electrician.
Important! Always switch off the electricity supply at the mains
during installation and maintenance. We recommend that the
fuse is withdrawn or circuit breaker switched off at the
distribution board whilst work is in progress.
This product must be earthed – if no earth feed wire is available,
consult an electrician.
Means for disconnection must be incorporated in the fixed
wiring in accordance with the wiring rules. To achieve this
install appropriate switched fused connection unit.
Note! A switched fused connection unit having a contact
separation of at least 3mm in all poles should be connected in
Electrical connection
GB GB
71
70
You should select a cooking temperature and function that is
appropriate for the food that you are cooking. You should also
ensure that the food is placed in an adequately sized dish and

Bekijk gratis de handleiding van Saba OMP7324BL/A, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkSaba
ModelOMP7324BL/A
CategorieFornuis
TaalNederlands
Grootte7918 MB