5
Î Release the lock (1).
Î Remove the pipe cutter from the tube.
Changing the blade
Caution: Always wear gloves during the operation of the guillotine pipe cutter. In this
way you will avoid seriously injuring yourself.
Î Open the lock (1).
Î Open the lower body (7).
Î Lower the blade holder (5) to the maximum by turning the handle (2).
Î Unscrew the 2 screws (8) with an Allen key.
Î Remove the blade (6) with care.
Î Put the new blade in place.
Î Tighten the screws (8).
Care and maintenance
• Clean the pipe cutter lubricator regularly.
• Grease the lubricator regularly.
Accessories
You can nd suitable accessories in the main catalog or at www.rothenberger.com.
Disposal
Components of the unit are recyclable material and should be put to recycling. For this purpose
registered and certied recycling companies are available. For an environmentalfriendly disposal of
the non-recyclable parts (e.g. electronic waste) please contact your local waste disposal authoritye.