4. CONTROLS
To activate the keyboard and its functions, press key A. All the LEDs light up at half intensity.
If it remains unused for approximately 15 seconds, it returns to stand-by.
Key Key Press Functions LED
A
Short Turns off the motor. -
B
Short Turns the motor on at the first speed. On/Off.
Long
24h Function
It activates/deactivates the motor in 24h Air Exchange mode. This
function sets the motor to the first speed which allows suction with
an interval of 10 minutes on and 50 minutes off.
It cannot be activated if the Delay function is active.
It is deactivated by pressing the same key or by switching off the
motor.
Flashes.
C
Short Turns the motor on at the second speed. On/Off.
D
Short Turns the motor on at the third speed. On/Off.
E
Short
Turns the motor on at the Intensive 1 speed.
This speed is timed for 10 minutes. At the end of this time, the sys-
tem automatically returns to the previously selected speed. If activ-
ated with the motor off, once the time has passed it switches to OFF
mode.
It is deactivated by pressing any speed button or by switching off
the motor.
It flashes once per
second.
Long
Turns the motor on at the Intensive 2 speed.
This speed is timed for 6 minutes. At the end of this time, the sys-
tem automatically returns to the previously selected speed. If activ-
ated with the motor off, once the time has passed it switches to OFF
mode.
It is deactivated by pressing any speed button or by switching off
the motor.
It flashes once
every 0.5 seconds.
F
Short
Delay Function
Activates/Deactivates the Delay function, the automatic delayed
shut-down of the motor and lighting system after 15 minutes.
Cannot be activated if the Intensive or 24H function is active.
It is deactivated by pressing the same key or by switching off the
motor.
On/Off.
G
Short Short press: Medium Light - Intense Light - Light Off. -
Long press (with
lights on)
To cyclically change the temperature of the light, perform several
long separate presses (5 steps).
This is used to vary the tone of light between "warm" and "cold".
-
H
Short
The Filter saturation alarm is reset.
All LEDs flash 3
times.
Long
Activates/Deactivates the Activated Carbon Filters alarm.
Alarm activated: all
the LEDs flash
twice.
Alarm deactivated:
all the LEDs flash
once.
- Signals the saturated Metal Grease Filters alarm and the need to
wash them. The alarm is activated after 100 hours of effective hood
operation.
LEDs H and C flash.
- Signals the Activated Carbon Odour Filter saturation alarm. The
alarm is activated after 200 hours of effective hood operation.
LEDs H and D flash.