4. CONTROLS
To activate the keyboard and its functions, press key A. All the LEDs light up at half intensity.
If it remains unused for approximately 15 seconds, it returns to stand-by.
Key Key Press Functions LED
A
Short Turns off the motor. -
B
Short Turns the motor on at the first speed. On/Off.
Long
24h Function
It activates/deactivates the motor in 24h Air Exchange mode. This function
sets the motor to the first speed which allows suction with an interval of 10
minutes on and 50 minutes off.
It cannot be activated if the Delay function is active.
It is deactivated by pressing the same key or by switching off the motor.
Flashes.
C
Short Turns the motor on at the second speed. On/Off.
D
Short Turns the motor on at the third speed. On/Off.
E
Short
Turns the motor on at the Intensive 1 speed.
This speed is timed for 10 minutes. At the end of this time, the system auto-
matically returns to the previously selected speed. If activated with the motor
off, once the time has passed it switches to OFF mode.
It is deactivated by pressing any speed button or by switching off the motor.
It flashes once per
second.
Long
Turns the motor on at the Intensive 2 speed.
This speed is timed for 6 minutes. At the end of this time, the system automat-
ically returns to the previously selected speed. If activated with the motor off,
once the time has passed it switches to OFF mode.
It is deactivated by pressing any speed button or by switching off the motor.
It flashes once
every 0.5 seconds.
F
Short
Delay Function
Activates/Deactivates the Delay function, the automatic delayed shut-down of
the motor and lighting system after 15 minutes.
Cannot be activated if the Intensive or 24H function is active.
It is deactivated by pressing the same key or by switching off the motor.
On/Off.
G
Short Short press: Medium Light - Intense Light - Light Off. -
Long press
(with lights on)
To cyclically change the temperature of the light, perform several long separ-
ate presses (5 steps).
This is used to vary the tone of light between "warm" and "cold".
-
H
Short
The Filter saturation alarm is reset.
All LEDs flash 3
times.
Long
Activates/Deactivates the Activated Carbon Filters alarm.
Alarm activated: all
the LEDs flash
twice.
Alarm deactivated:
all the LEDs flash
once.
- Signals the saturated Metal Grease Filters alarm and the need to wash them.
The alarm is activated after 100 hours of effective hood operation.
LEDs H and C flash.
- Signals the Activated Carbon Odour Filter saturation alarm. The alarm is activ-
ated after 200 hours of effective hood operation.
LEDs H and D flash.
5. LIGHTING
• Please contact the Service Depart-
ment to change it ("Please contact
the service department to purchase
it").
12