3.17. Word Clock
Word clock can be sent and received via 75 Ω coaxial cabling at the corresponding BNC connectors.
The cable length should not exceed 100 m (330 ft).
The input is terminated with 75 Ω internally. To pass on the word clock to other devices,
use the word clock output. Do not connect a T-adapter to the word clock input.
The state of an incoming word clock signal can be accessed in the CLOCK section.
Possible States:
• A green indicator shows that the signal is currently in sync with the chosen clock master.
• A light yellow indicator means that a word clock is received but is not in sync.
• A red indicator means that word clock is chosen as reference, but a signal is not present or has a
different sample rate than device.
The state of an incoming word clock signal can be observed in the CLOCK section.
RME 12Mic-D User’s Guide
3.17. Word Clock | 20