Rinnai 26 GD OIM
Floor Mounting
There are no specic requirements for oor mounting of the appliance other than those that are listed under
"Appliance Location" on page 24. When appliance is oor mounted, 'Embossment A' on the rubber feet does
not need to be cut out.
Bench or Shelf Mounting
Position the appliance in accordance with the requirements listed under "Appliance Location" on page 24.
When bench or shelf mounted, the appliance is supported by the four ‘feet’ at the base of the appliance. These
need to be fastened or secured to the bench or shelf.
Create threads on all four mounting holes on the unit by screwing the supplied screws all the way through and then
remove them. Then use appropriate screws (eld supplied) to attach the dryer onto the bench.
CAUTION
If the screws used are too long, they may cause damage to the dryer.
The recommended length of screw is 35mm plus thickness of the bench. The following items must be considered:
The bench or shelf and it’s support(s) should be of su󰀩cient strength and construction to support the weight of a
fully loaded dryer plus the weight of any other goods it is intended to support. The loaded weight allowances is
55kg.
Stability of the appliance. The bench or shelf dimension must have at least the same width and depth as that of the
appliance to provide su󰀩cient area to support the four ‘feet’ at the base of the appliance and allow for slight
movement that may occur during operation.
Wall Mounting
Position the appliance in accordance with the requirements listed under "Appliance Location" on page 24.
If the dryer is to be wall mounted, the following must be considered:
Only the Rinnai wall mounting bracket must be used DS9BKT. Alternative brackets or wall mounting options are
unsuitable.
The wall and method for fastening the wall mounting bracket to the wall must be of su󰀩cient strength and
construction to support the weight of a fully loaded dryer. The loaded weight allowances is 70 kg.
The four ‘feet’ at the base of the appliance must be securely fastened to the base of the mounting bracket using
the 4 mounting screws supplied ("Wall Mounting Bracket & Dryer Installation" on page 27).