Rinnai A Series handleiding

28 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 22 van 28
Rinnai 22 Evap AC OM
Q. Can I run the system when I am not home?
A. Evaporative cooling relies on doors and/or windows being open so you can run it when you are not home,
provided you have the required ventilation openings.
Q. How many doors and windows should I have open?
A. Refer to the section on openings required. The table gives a guide to the amount of opening area required for
each model in m
2
, and also gives suggestions on how to provide this.
Q. Why is there condensation and moisture on my tiles?
A. Make sure the vents are directed across the room and not towards the oor. Make sure su󰀩cient doors and
windows are open. Refer to the section on openings required. If it is a humid day turn the pump o󰀨.
Q. There is no air coming out of some of the vents
A. It is highly probable that this is an installation issue. Please contact your installer in the rst instance.
Q. What does duct cleaning entail?
A. Like any other part of your home dirt, dust and other foreign particles can accumulate and breed in the
ductwork and on system di󰀨users.
Remove dust from your cooling system
Kill any potential dust mites living & breeding throughout your cooling system
Remove odours from your cooling system
Helps improve indoor air quality
Allergy su󰀨erers may benet from clean ducts
Clean the Cooler fan and assembly
Clean the Supply air di󰀨users
Q. Can I run heating through the same ductwork as my evaporative cooler?
A. No, the di󰀨ering technology between ducted heating and evaporative cooling doesn’t allow the units to share
the same ductwork. Also, evaporative cooling requires larger ductwork for airow.
Q. How far should my cooler be away from sanitary vents?
A. The unit should be at least a 5 metre radius away from a sanitary outlet.
Q. How cool is cool?
A. The degree of cooling available from any type of air conditioning, is dependent on the outside weather
conditions. Your Evaporative Cooler works best on hot, dry days. After all, that’s when you require the most
relief.
Q. Should the unit have its own circuit in the meter box?
A. Yes, we recommend the power socket is wired back to the meter box on a dedicated power circuit.
Q. Should water be coming out of my evaporative cooler during operation?
A. Rinnai A Series and models will complete a ush service approximately every 20 cycles of the pumps
operation. This means you will see the unit dump the water out of the overow pipe.
Rinnai C Series models will not dump any water during operation as they are tted with an AquaSave which
operates to keep the water clean.
Q. Why doesn't my evaporative cooler turn on when the current time and room temperature is displayed yet the
word 'COOLER' is not?
A. Your evaporative cooler has lost communication with your Networker Wall Controller, a service call is required
Q. We have a unit with a Networker Wall Controller. How is the LED screen backlight activated without changing
any setting? Is there one key to press that activates the backlight without a󰀨ecting the current controller
function?
A. The LED backlit screen can be activated by pressing the Function key (Fn button).