Rigol MHO2034 handleiding
Handleiding
Je bekijkt pagina 85 van 332

• Center: when the horizontal time base is modified, the waveform will be
expanded or compressed horizontally relative to the screen center.
• Left: when the horizontal time base is modified, the waveform will be expanded
or compressed horizontally relative to the leftmost position of the screen.
• Right: when the horizontal time base is modified, the waveform will be
expanded or compressed horizontally relative to the rightmost position of the
screen.
• Trigger: when the horizontal time base is modified, the waveform will be
expanded or compressed horizontally relative to the trigger point.
• User: when the horizontal time base is modified, the waveform displayed will be
expanded or compressed horizontally relative to the user-defined reference
position.
When you select "User", click or tap the input field of
User Expansion. Input the
horizontal expansion reference value with the displayed numeric keypad. Its
range is from -500 to 500. Its default value is 0.
7.6 Roll Mode
In Roll mode, the waveforms are updated rolling from right to left on the screen. You
do not need to wait until all the complete waveforms are acquired. You can see the
acquired data points at any time during its acquisition. In the Horizontal system
menu, click or tap to select "Auto" or "OFF" for the Roll menu.
• Auto: enables the Roll mode. When the horizontal time base is set to 50 ms/div
or lower than the value, the instrument automatically enters the roll mode.
• OFF: disables the Roll mode. In this mode, when the horizontal time base is set
to 200 ms/div or lower than this value, the instrument enters slow sweep mode.
In this mode, the instrument first acquires the data at the left of the trigger point
and then waits for a trigger event. After the trigger occurs, the instrument
continues to generate the waveform at the right of the trigger point. When
observing the low-frequency signal in the slow sweep mode, it is recommended
that you set "
Channel Coupling
" to "DC".
TIP
• If the current delayed sweep is enabled, then when you enable the Roll mode, the
delayed sweep is disabled automatically.
• The following functions are not available when the Roll mode is enabled:
To Adjust the Horizontal Position
(available when the operating status of the oscilloscope
is in STOP state),
Zoom Mode (Delayed Sweep)
,
To Trigger the Oscilloscope
,
Pass/Fail Test
,
Waveform Recording and Playing
,
Persistence Time
,
Average
, and
XY Mode
.
Acquisition System
Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved. MHO2000 User Guide
67
Bekijk gratis de handleiding van Rigol MHO2034, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Rigol |
| Model | MHO2034 |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 47982 MB |