- Click or tap the input field of BX and use the pop-up numeric keypad to set
the horizontal position of Cursor B (X cursors). Its adjustable range is
limited within the screen.
- Click or tap the ON/OFF tab for AX BX to adjust the horizontal positions of
Cursor A and Cursor B (X cursors) simultaneously. The horizontal spacing
between Cursor A and Cursor B (X cursors) remains unchanged.
• When "Y" is selected for the track mode, you can adjust the position of Y cursor.
- Click or tap the input field of AY and use the pop-up numeric keypad to set
the vertical position of Cursor A (Y cursor).
- Click or tap the input field of BY and use the pop-up numeric keypad to set
the vertical position of Cursor B (Y cursor).
- Click or tap the ON/OFF tab for AY BY to adjust the vertical positions of
Cursor A and Cursor B (Y cursors) simultaneously. The vertical spacing
between Cursor A and Cursor B (Y cursors) remains unchanged.
You can also use the multifunction knob
on the front panel to adjust the cursor
position.
Minimize the Cursor Setting Window
Click or tap the ON/OFF tab for Minimize to select whether to minimize the window.
When you select ON, the cursor setting window will be minimized and displayed the
cursor menu at the right section of the screen, making the waveform view look more
simplified and concise. When you select OFF, the cursor setting menu window is
displayed on the screen. In the minimized window, click or tap
Max to maximize the
cursor setting window, and it will be displayed on the main screen again. Click or tap
Close to close the window.
Measurement Example
Set
Source A to CH1, Source B to CH2, and Track to "X".
When you adjust the AX cursor position, the AY cursor will automatically track the
crossing point between AX cursor and the waveform of the specified channel (CH1);
When you adjust the BX cursor position, the BY cursor will automatically track the
crossing point between the BX cursor and the waveform of the specified channel
(CH2). The measurement results are displayed in the result list, as shown in
Figure
10.10
. Then, expand the waveforms horizontally, and you will find that the cursor will
track the point that has been marked, as shown in
Figure 10.11
.
Measurements
MHO2000 User Guide
164
Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
Bekijk gratis de handleiding van Rigol MHO2034, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.