COMMISSIONING
41
PRESET OUTLET TEMPERATURE SETTING
The factory preset outlet temperature setting of the water heater is:
• 874 series 60°C
• 876 series 50°C
If a temperature controller is connected to the water heater, this will override the preset outlet temperature
setting and the maximum temperature setting will be:
Maximum Outlet Temperature
874 series
876 series
Kitchen controller connected 60°C 50°C
Bathroom controller only connected 50°C 50°C
It is usually not necessary to adjust the factory preset outlet temperature setting of the water heater, unless
the customer has a particular requirement for this to be done or it is to be installed as an in-series gas booster
to a solar water heater.
Refer to “To Check or Adjust the Preset Outlet Temperature Setting” on page 41 to check or if required to
adjust the preset outlet temperature setting of the water heater.
Gas Booster for a Solar Water Heater
Note: Australian Standard AS 3498 requires that a water heater provides the means to inhibit the growth of
Legionella bacteria in potable water. When the 874 series water heater is used as an in-series booster for a
solar water heater it can satisfy this AS 3498 requirement provided it is energised, the booster preset outlet
temperature setting is 70°C or higher, and that a remote temperature controller is not used.
It will be necessary to check and if required to adjust the preset outlet temperature setting of the continuous
flow water heater when:
• it is installed as an in-series gas booster to a solar water heater
• it is an existing continuous flow water heater and a solar water heater is then installed.
Notes
• Consideration must be given to the delivery temperature to any ablution and public areas such as a
bathroom, ensuite or public amenities. Refer to “Hot Water Delivery” on page 24.
• The 876 series water heater, marked “THIS APPLIANCE DELIVERS WATER NOT EXCEEDING 50°C IN
ACCORDANCE WITH AS 3498” on the front panel, must not be installed as an in-series gas booster to
a solar water heater, as water temperature greater than 50°C can be delivered from the water heater
contravening its compliance to AS 3498.
TO CHECK OR ADJUST THE PRESET OUTLET TEMPERATURE SETTING
The temperature setting will be displayed on the LED display. The preset outlet temperature settings are:
• 874 series 40°C, 42°C, 45°C, 50°C, 60°C, 65°C, 70°C, 75°C
• 876 series 40°C, 42°C, 45°C, 50°C
It is necessary to have the electrical supply to the water heater switched on during stages of checking or
adjusting the preset outlet temperature setting procedure.
Warning: The removal of the front panel will expose 220 V - 240 V a.c. wiring. Take care not to touch wiring
terminals. The adjustment must be carried out by a qualified person.
Warning: This procedure will involve the adjustment of dip switches. Adjustment of a dip switch should
only be made with an insulated tool.