INSTALLATION
30
TECHNICAL DATA
Models
Gas type suffix
874A12
876A12
NF, PF
874A16
876A16
NF, PF
874A20
876A20
NF, PF
874A26
876A26
NF, PF
Water heating capacity
@ 40°C rise
litres / min
7.5 10.0 12.5 16.2
Nominal capacity
@ 25°C rise
litres / min
12 16 20 26
Mass Empty (unpackaged)
kg
17.5
17.5
17.5
17.5
Gas Details
Hourly Gas Consumption
(MJ)
Min. Gas
Pressure
(kPa)
Max. Gas
Pressure
(kPa)
Injector Size (mm)
40 x injectors
per water heater
A12
A16
A20
A26
A12, A16, A20, A26
A12, A16, A20, A26
Natural
95
126
157
199
1.13
3.50
20 x
∅
1.55 + 20 x
∅
1.03
Propane
95
126
157
199
2.75
3.50
20 x
∅
1.10 + 20 x
∅
0.73
Gas Details
Test Point Gas Pressure (kPa)
minimum
maximum
874A12
876A12
874A16
876A16
874A20
876A20
874A26
876A26
874A12
876A12
874A16
876A16
874A20
876A20
874A26
876A26
Natural
0.160
0.160
0.160
0.160
0.520
0.423
0.630
0.950
Propane
0.190
0.190
0.190
0.190
0.615
0.490
0.705
1.075
Technical data is subject to change.
Model numbers
• Gas type Letter N or P is included in the model number to denote gas type.
N = Natural, P = Propane.
E.g. 874A26NF, 874A26PF.
• Frost protection Letter F is included in the model number to denote frost protection.
• Solar boosters /J is included in the model number to denote a Joey Grey coloured jacket.
These models are used as solar booster water heaters.
Available on 874A20NF/J, 874A26NF/J, 874A26PF/J models.