INSTALLATION
28
FROST PROTECTION
The water heater has a frost protection system. The frost protection system will protect the water heater from
damage, by preventing ice forming in the waterways of the water heater, in the event of freezing conditions
occurring.
The frost protection system will be rendered inoperable if electrical power is not available at the water heater.
Damage to the water heater caused by freezing of the pipe work to or from the water heater is not covered
under the Rheem warranty. Refer to AS/NZS 3500.4 for precautions to be taken for installations in frost prone
areas. The water heater is not suitable for installation in areas where the ambient temperature falls below -
20°C (including wind chill factor).
The cold water line to the water heater must be insulated with suitable thickness insulation if freezing conditions
are likely to occur. The insulation must be fitted to the underside of the water heater and be weatherproof and
UV resistant if exposed.
TEMPERATURE CONTROLLERS
The Rheem 874 and 876 series can be installed with Rheem Standard controllers to enable the user to control
the temperature of the delivered water from the outlet of the water heater.
There are three types of Standard controller. They are the Kitchen controller, Bathroom 1 controller and the
Bathroom 2 controller. The controllers are designed to be hard wired into the water heater using either the
Kitchen controller cable or the Bathroom controller cable.
Temperature controllers are only suitable for single water heater installations. They are not suitable if multiple
water heaters are manifolded together. Other manufacturers’ controllers are not suitable to and cannot be
installed with this water heater.
Warning: Temperature controllers must not be fitted to this water heater (874 series) if it is installed as an
in-series gas booster with a solar water heater system because water at a temperature much higher than the
controller setting can be delivered. If a solar water heater is installed to an existing water heater installation,
then all controllers must be disconnected and removed.
Refer to the Rheem website for the Owner’s Guide and Installation Instructions for the Standard Rheem
Controllers. Visit – www.rheem.com.au/rheem/help#guides.
REDUCING HEAT LOSSES
The hot water line from the water heater and the pipe work between the solar storage tank, if one is installed,
and the in-series gas booster must be insulated in accordance with the requirements of AS/NZS 3500.4. The
insulation must be weatherproof and UV resistant if exposed. The insulation must be fitted up to the
connections on the both the underside of the water heater and the solar storage tank.