Respekta Svea CH22010WBZ handleiding

69 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 64 van 69
en-29
English
5.2.10 Installation of the hood for air extraction type operation
The wall opening must be sized for a 150mm diameter exhaust air duct. (Make a hole of approximately
155mm in diameter ).
To install the hood in extraction mode, fit it as described in the previous section: “Mounting the hood",
without fitting the charcoal filters.
Proceed as follows during the installation work:
1 - Remove the external and internal chimneys;
2 - Fit the exhaust duct;
3 - Refit the external and internal chimneys;
Fig. 5.18
For final installation of the hood in extraction mode, an
air outlet grille will be required with a 150mm fitting (a)
for connection to the air exhaust duct. The grille is not
supplied with the hood.
a)
Fig. 5.19

Bekijk gratis de handleiding van Respekta Svea CH22010WBZ, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkRespekta
ModelSvea CH22010WBZ
CategorieAfzuigkap
TaalNederlands
Grootte7226 MB