10 Troubleshooting and customer service
The unit has been manufactured using state-of-the-art production methods and has been tested several
times to ensure that it works properly. If malfunctions should occur, please check the unit as detailed in the
list below. Please inform your dealer if the unit is still not working correctly after all the function checks have
been performed.
Operational malfunctions
Fault description Cause Remedy
The unit does not start or switches
itself off.
Master switch off. Switch on the master switch.
Power failure Check voltage and if necessary
wait until turned on again
Defective mains fuse Arrange to have exchanged
Power supply defective Repair by specialist firm.
Operational temperature range
too low or exceeded.
Observe operational tempera-
ture range 16 to 35 °C.
Internal reservoir full. Empty reservoir.
The ambient temperature of the
unit lies outside the operating
range.
Do not operate the unit outside
the operating range.
The unit does not work or works at
reduced cooling capacity.
Filter contamination, inlet and/or
outlet blower openings blocked by
foreign bodies.
Clean the filter.
Windows and doors open/heat
load was increased.
Close doors and windows/
reduce heat load.
"Cooling" operating mode is not
selected.
Set "Cooling" operating mode.
Unit will be switched by means of
the timer function.
Press "I/0" key again.
Temperature setting too high. Reduce temperature.
Overvoltage due to local lightning
strike.
Switch unit off and separate
from the power supply for 5
mins., then start anew.
Condensate discharge on unit. Unit standing at an angle. Stand vertically.
The stopper for the condensate
drain is not correctly inserted or is
damaged.
Insert stopper correctly or
replace if necessary.