Condensate drainage
In cooling mode, the condensate produced is con-
tinuously pumped via the connecting line into the
outdoor unit, where it is centrifuged to the con-
denser and finally evaporates. Excess condensate
that cannot be removed in this way is drained off
via the condensate drain on the outdoor unit. To
prevent an uncontrolled overflow of the conden-
sate, it is recommended to leave the condensate
drain permanently open and to securely connect it
with the supplied hose.
Fig. 12: Overflow on the outdoor unit
Emergency drainage
Under certain conditions, such as high humidity,
the condensate may not be removed quickly
enough by the condensate pump and may collect
in the condensate tray of the indoor unit. If the con-
densate tray is full, the display shows the error
code "FL". In this case, the condensate must be
drained via the emergency drainage
Fig. 13: Emergency drainage on the indoor unit
7 Commissioning
Before every commissioning the air inlet and outlet
openings should be checked for foreign bodies and
the air inlet filter must be checked for dirt. Blocked
or soiled grills and filters must be cleaned immedi-
ately, see "Care and maintenance" chapter.
REMKO SKC series
18