Function table:
Functions
Power plug
inserted
Operating status: Unit
operating or in standby
Defrost function
Full tank
function
OFF
(no opera-
tion)
Standby
(no opera-
tion)
r RH <-3%
The unit
starts
r
RH >+4%
30 min. timer
expires if
T
e<=1 °C
After the
30 mins.
defrost timer
function has
passed
A Comp. ON LED OFF Flashes ON ON ON OFF
B Check LED OFF OFF OFF OFF OFF Flashes
C Defrost LED OFF OFF OFF Flashes
ON
If
T
e >=3 °C,
then OFF
OFF
D Full Tank LED OFF OFF OFF OFF OFF Flashes
E Solenoid valve OFF OFF
ON
for 10 sec.
then OFF
OFF
ON
If
T
e >=3 °C,
then OFF
OFF
F Fan motor OFF OFF
ON
after
10 sec.
ON
OFF
If
T
e >=3 °C,
then ON
OFF
G Compressor OFF OFF
ON
after
10+0.5 sec
ON ON OFF
H
Humidity seg-
ment display [3]
Current room humidity is displayed
I
Operating
hours / power
consumption
segment dis-
play [6]
Operating hours or power consumption are displayed
(changeover by actuating the "h/kWh" key)
21