The time can be programmed by pressing the CLOCK button. The time
blinks in the display and the current time can be set using the HR. and
MIN. button. Programming is completed by pressing the CLOCK button,
the display will stop blinking.
CLOCK Button (recessed)
The fan speed can be adjusted with this button. A selection can be made
between low, medium, high and automatic fan speed.
FAN Button
In dehumidification mode, the room temperature cannot be set. Due
to the low temperature of the refrigerant, the dew point of the air at the
condenser is undercut. The excess moisture in the air is condensed on the
condenser, the room is dehumidified. The fan has four speeds. Neither
the ion generator nor turbo mode can be selected in this mode.
Dehumidification MODE
DEHUMIFICATION
MODE
MODE
30 sec.
Nominal temperature
Nominal temperature -2°C
Fan operation IT
Fan operation AT
Compressor operation AT
Actual temperature
Start
Dehumidifying mode
Dehumidifying mode
Stop
Dehumidifying mode
Functional diagram
Operation
Stop
Low fan speed
CLOCK
CLOCK
HR./MIN.
FANFANFAN FAN
The speed change is achieved with a phase control. When switching
between individual speeds, virtually no audible difference is
noticeable.
NOTE