8. Technical Data
The hob is an independent Class 3 built-in unit.
This hob is category II
2H3+
It is supplied set for group H natural gas. A conversion kit from NG to LP is available for the hob.
INSTALLER: Please leave these instructions with the user.
DATA BADGE LOCATION: Base of the hob.
COUNTRY OF DESTINATION: GB/IE
Connections
Gas Electric
Rp ½ at rear right-hand side 230V~50Hz
Gas Electric
Natural Gas 20 mbar 230V~50Hz
Butane 29 mbar
Propane 37 mbar
(See appliance data badge for test pressures)
Dimensions
Outside Inside
Width 500 mm 470 mm
Length 600 mm 550 mm
Depth 50 mm from top 40 mm
Mass (kg) 11.5
Space for xing See Positioning of the Hob “Fig. 5.1” on page 10
Minimum space above hotplate See Positioning of the Hob “Fig. 5.1” on page 10
Ratings
Natural Gas L.P. Gas
Hotplate Injector Injector
Triple Burner 3.8 kW 135 3.8 kW (277 g/h) 98
Semi-rapid Burners 1.75 kW 97 1.75 kW (127 g/h) 65
Auxilliary Burner 1.0 kW 72 1.0 kW (73 g/h) 50
Gas burner inputs based on Gross Caloric Value